Search  
 



Contac
t us

SAFDRY electrodes

SAF has created the range of SAFDRY electrodes which present the following advantages :

  • No drying is required

  • Pre-heating is reduced or even eliminated, however this will have to be verified in situ

This is made possible thanks to the special manufacturing process of SAFDRY :

  • Very low hydrogen content in the coating

  • This very low hydrogen content is maintained by the vacuum packing technology

  • The high-tech coating absorbs moisture so slowly that SAFDRY electrodes can be used for at least 8 hours after opening the packet.

SPECIAL CHARACTERISTICS

diffusible H2 in ml/100 g deposited metal
Electrode name
on removal from the packet
after exposure to air with
80% humidity at 27°C - Air speed >= 0.5 m/s
4 hours
8 hours
2.7
3.7
4.7
3.0
4.3
4.9
3.0
4.5
5.2
3.0
4.5
5.2
3.0
4.5
5.2
3.2
3.9
5.4
2.8
3.8
4.8
2.6
3.0
3.5
3.1
4.0
5.3
3.2
4.1
5.4
3.2
4.1
5.4
3.2
4.1
5.4
2.8
3.8
4.8
2.8
3.8
4.8
2.5
2.8
3.5
3.0
3.9
4.7
2.5
3.3
4.0
2.5
3.3
4.0
2.5
3.3
4.0
3.5
4.0
4.5
 
Total hydrogen 3.4 ml/100 g